Back to top
08045476609
Send SMS Send Inquiry
                                          Most Popular Products


                                          Galvanostatic charge and discharge (GCD) Testing Services
                                          Galvanostatic charge and discharge (GCD) Testing Services
                                          Galvanostatic charge and discharge (GCD) Testing Services
                                          Galvanostatic charge and discharge (GCD) Testing Services
                                          Galvanostatic charge and discharge (GCD) Testing Services
                                          Galvanostatic charge and discharge (GCD) Testing Services

                                          Galvanostatic charge and discharge (GCD) Testing Services

                                          Price 4800.0 INR/ Unit

                                          MOQ : 100 Units

                                          Galvanostatic charge and discharge (GCD) Testing Services Specification

                                          • Power
                                          • 230V AC / 50 Hz
                                          • Weight
                                          • Depends on sample; compatible up to 100g
                                          • Size
                                          • Customizable cell sizes, Standard options available (e.g., 2016, 2032 coin cell formats)
                                          • Interface
                                          • USB, Ethernet, RS232 (system dependent)
                                          • Voltage
                                          • 5 V (Standard), up to 10 V (Advanced models)
                                          • Frequency
                                          • DC
                                          • Material
                                          • Stainless Steel, Electrochemical grade materials
                                          • Measuring Range
                                          • Current range: 1 A to 5 A (model dependent)
                                          • Usage & Applications
                                          • Battery research, Supercapacitor analysis, Electrochemical device evaluation
                                          • Driven Type
                                          • Fully automatic, Computer-controlled
                                          • Display
                                          • Digital (PC-based interface, software-supported)
                                          • Temperature
                                          • Room temperature to 60C (optional temperature control)
                                          • Channels
                                          • Multi-channel support (typically 8, 16, or 32 channels per system)
                                          • Sampling Rate
                                          • Up to 10 ms interval (model dependent)
                                          • Control Software
                                          • Supplied with proprietary analysis software for curve plotting and parameter extraction
                                          • Calibration
                                          • Factory calibrated; user calibration function available
                                          • Safety Features
                                          • Overcurrent, overvoltage, and temperature protection
                                          • Lead Time
                                          • Typically 1-2 weeks from order
                                          • Ambient Humidity
                                          • 20% to 80% RH (non-condensing)
                                          • Sample Type
                                          • Compatible with electrodes, full cells, coin cells, pouch cells, etc.
                                          • Data Recording
                                          • Real-time data acquisition, export in multiple formats (CSV, TXT, etc.)
                                          • Test Duration
                                          • Supports extended cycling, programmable from seconds to thousand-hour tests
                                          • Modes of Operation
                                          • Constant current charging/discharging (Galvanostatic), programmable current profiles
                                          • Compliance
                                          • CE marked; supports GLP/GMP quality guidelines
                                           

                                          Galvanostatic charge and discharge (GCD) Testing Services Trade Information

                                          • Minimum Order Quantity
                                          • 100 Units
                                          • Delivery Time
                                          • 15 Days
                                           

                                          About Galvanostatic charge and discharge (GCD) Testing Services

                                          Mett-bios india based iso 17025:2017 (NABL) accredited testing laboratory is pleased to introduce as a leading laboratory to provide complete metallurgical and corrosion testing as per NACE/ ASTM / ISO standards.

                                          We are committed to delivering accurate, reliable, and standards-compliant Galvanostatic change and discharge (GCD) testing solutions as per ASTM, ISO, JSI, EIL, TL and NACE standards with fast turnaround time and expert technical support.

                                          Mett-bio through its team of experts offers specialized services in the field of metallurgical and corrosion failure investigation. The laboratory scope includes failure analysis of industrial plants, equipment and components, in-situ metallography, assessment of in-service degradation, components/parts indigenization, selection of materials and alloy design, remaining life assessment.

                                          Mett-bio has set up a fully-fledged advanced testing division at Ahmedabad to fulfil the industries requirements for testing and material characterization such as raw material testing, corrosion testing & analysis, material identification, microstructure examination for evaluation of material processing, chemical properties & physical properties of metallic materials

                                          Mett-Bio metallurgical services provide various corrosion-related services such as testing, onsite corrosion assessment, corrosion failure mode analysis, R&D, alloy selection, etc. Our services mainly cater to the needs of oil, gas, pharmaceutical, food and safety industries, ferrous and nonferrous manufacturing industries.



                                          Advanced Multi-Channel Testing

                                          Our service provides flexible multi-channel support, allowing simultaneous testing of multiple samples-essential for high-throughput research environments. Each channel operates independently and supports coin cells, pouch cells, electrodes, and full cells, maximizing productivity and experimental versatility.


                                          Comprehensive Safety and Compliance

                                          Safety is prioritized through features like overcurrent, overvoltage, and temperature protections, all enclosed in CE-marked equipment built from premium materials. The systems fully comply with GMP/GLP guidelines, meeting industry standards for quality and traceability, essential for regulated laboratory and industrial applications.


                                          Powerful Data Management and Analysis

                                          With real-time data recording, customizable export formats, and robust proprietary software, users can efficiently analyze charge/discharge curves and extract key parameters. The interface supports USB, Ethernet, and RS232, ensuring seamless connectivity and integration into varied laboratory setups.

                                          FAQ's of Galvanostatic charge and discharge (GCD) Testing Services:


                                          Q: How does the GCD Testing Service accommodate different sample types and cell formats?

                                          A: Our GCD testing services are compatible with electrodes, full cells, coin cells, and pouch cells. We offer customizable test fixtures and standard options (such as 2016, 2032 coin cell formats), making it easy to test various sample sizes and configurations up to 100g.

                                          Q: What kind of tests and operation modes are available?

                                          A: We support constant current charge/discharge (galvanostatic mode) and programmable current profiles, accommodating a wide range of research and evaluation protocols. Test cycles can be tailored from seconds to several thousand hours, ensuring flexibility for long-term cycling and rapid testing applications.

                                          Q: When is real-time data acquisition and analysis possible, and how is the data managed?

                                          A: Real-time data acquisition is enabled throughout the test, with fast sampling rates up to 10 ms depending on the system model. Data can be exported in multiple formats (CSV, TXT, etc.) and analyzed with our proprietary software, which facilitates curve plotting and parameter extraction.

                                          Q: Where is compliance and quality assured in your testing services?

                                          A: Our systems are CE marked and adhere to GLP/GMP quality guidelines, ensuring both regulatory compliance and traceable, high-quality results. Calibration is done at the factory, with user calibration available to maintain accuracy during extended use.

                                          Q: How does the service ensure safety during testing procedures?

                                          A: Comprehensive safety features include overcurrent, overvoltage, and temperature protection. Optional temperature control allows testing from room temperature up to 60C, minimizing risks to both the operator and equipment during critical experiments.

                                          Q: What are the main benefits of using this GCD Testing Service for battery and supercapacitor research?

                                          A: With multi-channel systems, fully automated operation, robust data management, and customizable settings, our service enables efficient, reproducible, and detailed electrochemical performance evaluation. This helps accelerate R&D, facilitates advanced device analysis, and optimizes product development cycles.

                                          Tell us about your requirement
                                          product

                                          Price:

                                          Quantity
                                          Select Unit

                                          • 50
                                          • 100
                                          • 200
                                          • 250
                                          • 500
                                          • 1000+
                                          Additional detail
                                          Mobile number

                                          Email

                                          More Products in Testing Services Category

                                          Multi Potential Steps Testing Services

                                          Multi Potential Steps Testing Services

                                          Price 5800.0 INR / Unit

                                          Minimum Order Quantity : 100 Units

                                          Usage & Applications : Electrochemical analysis, corrosion studies, battery research

                                          Driven Type : Electric

                                          Display : Digital LCD Display

                                          Temperature : 10C to 45C

                                          Integrated Pulse Amperometric Detection (IPAD) Testing Services

                                          Integrated Pulse Amperometric Detection (IPAD) Testing Services

                                          Price 7000.0 INR / Unit

                                          Minimum Order Quantity : 100 Units

                                          Usage & Applications : Laboratory, Pharmaceutical, Food Analysis, Chemical Research

                                          Driven Type : Electric

                                          Display : Digital

                                          Temperature : Room Temperature

                                          Galvanostatic EIS vs Time Testing Services

                                          Galvanostatic EIS vs Time Testing Services

                                          Price 8500.0 INR / Unit

                                          Minimum Order Quantity : 100 Units

                                          Usage & Applications : Battery lifetime evaluation, corrosion studies, electrochemical research, and diagnostics

                                          Driven Type : Computercontrolled, galvanostatic mode

                                          Display : Digital (softwarebased) realtime monitoring

                                          Temperature : Controlled conditions, ambient to 70C

                                          Cyclic Voltammetry (CV) Testing Services

                                          Cyclic Voltammetry (CV) Testing Services

                                          Price 7500.0 INR / Unit

                                          Minimum Order Quantity : 100 Units

                                          Usage & Applications : Electrochemical analysis, battery research, sensor development, chemical and material testing

                                          Driven Type : Electronic/Potentiostatic

                                          Display : Software (Digital PC Interface)

                                          Temperature : Ambient (Room temperature) or controlled